Skip to main content
Version: v9

Safety states

The shield icon in the robot-status pill of the app bar shows the current safety state. Open the pill's menu to read its description.

ValueNameShown text
100MANUALManual Mode. Robot runs in reduced Velocity
200AUTOAuto Mode. No safety based restrictions apply
301SAFE_STOP_0Safety control SAFE_STOP_0 has triggered! Please recover Safety State manually.
302SAFE_STOP_1Safety control SAFE_STOP_1 has triggered! Please recover Safety State manually.
303SAFE_STOP_2Safety control SAFE_STOP_2 has triggered! Please recover Safety State manually.
304INVALIDInvalid operation mode! Either drive lost safe position and keyswitch in automatic mode or faulty keyswitch reading.
500ERRORError in safety control, please check connection or contact Customer Support.
501NOT_CONNECTEDSafety Controller not connected. Waiting for data

Invalid operation mode (304)​

INVALID is shown when the controller reports an invalid safety mode selection. It behaves like Safe Stop 1: the same actions are blocked.

Either a drive lost its safe position while the keyswitch is in automatic mode, or the keyswitch reading is faulty. Follow the safe position reset procedure in the Robot manual and check the keyswitch.

Other interfaces​

  • Over Profinet, the PLC sees the raw value 304 together with system_alarm_error.
  • Over OPC UA, INVALID maps to protectiveStop.

Generic Button​

The Safe Stop condition of the Generic Button also matches INVALID.