Safety states
The shield icon in the robot-status pill of the app bar shows the current safety state. Open the pill's menu to read its description.
| Value | Name | Shown text |
|---|---|---|
| 100 | MANUAL | Manual Mode. Robot runs in reduced Velocity |
| 200 | AUTO | Auto Mode. No safety based restrictions apply |
| 301 | SAFE_STOP_0 | Safety control SAFE_STOP_0 has triggered! Please recover Safety State manually. |
| 302 | SAFE_STOP_1 | Safety control SAFE_STOP_1 has triggered! Please recover Safety State manually. |
| 303 | SAFE_STOP_2 | Safety control SAFE_STOP_2 has triggered! Please recover Safety State manually. |
| 304 | INVALID | Invalid operation mode! Either drive lost safe position and keyswitch in automatic mode or faulty keyswitch reading. |
| 500 | ERROR | Error in safety control, please check connection or contact Customer Support. |
| 501 | NOT_CONNECTED | Safety Controller not connected. Waiting for data |
Invalid operation mode (304)
INVALID is shown when the controller reports an invalid safety mode selection. It behaves like Safe Stop 1: the same actions are blocked.
Either a drive lost its safe position while the keyswitch is in automatic mode, or the keyswitch reading is faulty. Follow the safe position reset procedure in the Robot manual and check the keyswitch.
Other interfaces
- Over Profinet, the PLC sees the raw value 304 together with
system_alarm_error. - Over OPC UA, INVALID maps to
protectiveStop.
Generic Button