Skip to main content
Version: v9

RobSafety

Welcome to the RobSafety knowledge base.

RobSafety lets you configure the Robot's Safety Functions and decide under which circumstances each one is activated or deactivated. Safety behavior is driven by the physical state of the Safe Inputs on the Control Unit, so the Robot can react to its surroundings — slowing down, restricting its Workspace, or stopping — without changing the Flow that is running.

Beta feature

RobSafety is a beta feature and is only available when the Robot's update channel is set to Beta.

note

RobSafety needs a V3 Robot. On a V2 Robot and on a virtual Robot the page says so and cannot be used.

How RobSafety is organized​

The RobSafety page has three tabs — Activation Rules, Safety Functions and Mapping — and a fourth, General Parameters, when the Robot's safety program has always-active global parameters (for example SF6 Sum of Joint Speeds and the SS1/SS2 deceleration limit):

  • Activation Rules — describe a state the Robot is in, expressed through the Safe Inputs on the Control Unit.
  • Safety Functions — the behaviors the Robot should follow, such as a Cartesian speed limit or a Safe Space it must stay inside or outside of.
  • Mapping — link Safety Functions to Activation Rules, so a function becomes active whenever its rule does.
New here?

Start with Getting started for a first configuration, then see Configuration for the details of each part and the Safety Functions reference for every function and its parameters.