Skip to main content
Version: v9

Configuring RobSafety

With RobSafety you can configure various Safety Functions and decide under which circumstances they should be activated or deactivated. The page has three tabs, Activation Rules, Safety Functions and Mapping, plus General Parameters when the safety program has them.

Activation Rules​

With Activation Rules you can define a certain state the Robot is in. The state is configured via the Safe Inputs on top of the Control Unit.

For each Safe Input you can decide whether you:

  • want to ignore it (leave the checkbox unchecked);
  • want it to be enabled (check the checkbox);
  • want it to be disabled (check the checkbox and the inverted checkbox right after).

Once the configured Safe Inputs exactly match the physical state of the Safe Inputs on the Control Unit, the Activation Rule is activated.

Safety Functions​

With Safety Functions you can configure different behaviors of the Robot — for example a Cartesian speed limit, or a Safe Space that the Robot must stay inside or outside of.

The always-active functions SF8 and SF9 are always listed. They cannot be deleted; Reset restores their default values.

Mapping​

With Mapping you link Safety Functions to Activation Rules. Once an Activation Rule becomes active (because the physical state of the Safe Inputs on the Control Unit matches), the linked Safety Functions become active too.

General Parameters​

The General Parameters tab appears when the safety program has always-active global parameters, such as SF6 Sum of Joint Speeds and the SS1/SS2 deceleration limit. You edit them like a Safety Function, and they are uploaded with the configuration.

Safety program CRC AFB​

The bottom-left corner of the RobSafety page shows Safety Program CRC AFB:. It shows one value when the safety program file on the Control Unit and the one on the Safety Controller agree. When they differ, or the Safety Controller has not been read yet (unknown), it shows both, as pmt2: … | scu: …. A difference is shown in red, and the message log then reports "The safety program on the Safety Controller (CRC AFB …) does not match the safety program file on the Control Unit (CRC AFB …). Please contact Customer Support." (error 283). On V2 and virtual Robots the value is n/a.

Use the value to confirm which safety program a Robot runs, for example for acceptance records.

The bottom-left corner of the RobSafety page showing the Safety Program CRC AFB valueThe bottom-left corner of the RobSafety page showing the Safety Program CRC AFB value