Running a Calibration

The entry point is Robot Configuration > Calibration. This is the right choice for first-time setup and for occasional re-calibration, since it gives you full access to every step and setting in the Flow.

Managing Calibrations​

Beyond running a calibration, the Calibration area gives you tools to manage the calibrations you already have.

Import and Export (top right) move a calibration between systems. The most common reason to use this is when you swap a Control Unit: export the calibration from the old unit before the swap, then import it onto the replacement so the Robot keeps its existing alignment without having to be recalibrated from scratch. On import you choose to apply the calibration directly, if the file holds a result and the Robot's modules match, or to keep it as a draft. Export also serves as a useful backup before you make significant changes.

Current calibration shows Custom calibration or Factory calibration, In use, the time it was applied and its RMSE. View measurements shows the stored samples. Deactivate returns the Robot to its factory calibration, the original, as-shipped one. This is helpful when a calibration has drifted or was set up incorrectly and you want a clean, known starting point before running a new calibration. Keep in mind that deactivating discards your current calibration, so export it first if there is any chance you will want it back.

If the Robot's modules no longer match the calibration, the card shows Ignored — modules changed. The Control Unit then plans with factory defaults until you run a new calibration or restore the original modules.

If you ever need to revert to a previous state, use Roll back → Restore. It re-applies the calibration that was active before the current one, straight away; no samples are re-collected.

Calibration in progress shows a draft (or a running or paused calibration Flow) with Resume / Open and Discard draft.

New calibration starts the setup described in the New Calibration section below.

Managing existing calibrationsManaging existing calibrations

New Calibration​

Creating a new calibration is a guided, four-step process. You move through the steps in order, and each one builds on the choices you made in the previous step.

Note: the product currently only allows for camera-based calibration. The laser calibration is only for RobCo internal use.

Step 1 — Sensor Type​

Start by choosing the type of sensor you are calibrating. Select the camera, depending on the hardware mounted on your Robot. This choice determines how the rest of the Flow behaves, so make sure it matches the actual sensor in use before continuing.

Calibration currently supports two device types. Both measure the calibration target's pose relative to the Robot — you only need one:

  • Camera — a RobVision camera that detects the target in its image. It takes several detections at each pose and averages the ones that agree, which makes it robust to noise.
  • Laser Tracker — a tracker that follows a mirror ball (SMR) for a high-precision, single-shot measurement. It needs a one-time base alignment so it knows where the Robot base sits in its own frame.

Step 2 — Edge Device and Camera​

Next, tell the system which edge device and camera to use. First select the edge device, then select the corresponding camera connected to that device.

Once the camera is selected, check the live picture carefully. The Robot, together with the calibration board, must be captured correctly and clearly in the frame. If the view is poor, for example if the image is too dark, too bright, out of focus, or the board is partly out of frame, use Camera settings to open the device in the Vision section and adjust exposure or brightness until the Robot and calibration board are clearly visible. Getting a clean image here is important, because the calibration relies on the camera seeing the board accurately.

Setting up a camera​

  1. Pick the Camera sensor type. On the device setup step, choose "Camera".
  2. Select the RobVision edge device. Under 2.1 Edge device, pick the RobVision Device the camera is attached to. Devices are created and managed in Robot Configuration → Vision. Here you only choose among them. Manage RobVision devices takes you there.
  3. Choose the camera. Under 2.2 Camera, pick which of the device's cameras points at the calibration target. If the device has only one camera it is selected automatically.
  4. Verify the live snapshot. The Camera view loads a snapshot automatically; compare it with What to capture, and use Refresh to re-check. A loaded snapshot means the camera is ready.

The target must stay visible and well-framed at every pose — a pose where it can't be detected is skipped. Frame it like this reference:

Calibration target framing example

Setting up a Laser Tracker​

  1. Pick the Laser Tracker sensor type and connect. Choose "Laser Tracker", enter the tracker's host (IP or hostname) and press "Connect". A green "Connected" chip confirms the link.
  2. Let the tracker warm up. If the tracker is still cold it warms up first — just wait for it to finish.
  3. Set the home position. Place the SMR (the mirror ball) directly in front of the tracker and press "Confirm Home Position". Live X/Y/Z coordinates appear once the tracker is tracking it.
  4. Record three base corners. Move the SMR to each of the three corners of the Robot base in turn and press "Record Position". If tracking is lost, return the SMR to home and continue.
  5. Let the base transform compute. After the third corner the base-to-tracker transform is computed and you see "Base registration complete" with its RMSE. The tracker is now ready to measure.

Step 3 — Calibration​

With the sensor and camera ready, you run the calibration itself.

3.1 Select Flow: pick a calibration Flow from the list, or select New Calibration Flow. Use Import Flow to load an exported one, and Open Editor to edit the selected one in the Calibration Editor (see Creating a new Flow). Each Flow in the list has the row actions Rename, Duplicate, Export and Delete (with Undo). Switching Flows while samples are collected asks Discard current calibration?

3.2 Run Flow: select Start Flow, then use Pause / Resume and Stop Flow. The section shows Movements collected, the sample count, the RMSE, the metrics and the joint coverage. Discard & start over clears the samples.

Start Flow stays disabled, with the reason shown as a tooltip, while no Flow is selected, the Robot is not in Teach Mode, is in Free Motion, has its brakes engaged, is not idle or is in a safety error, or its configuration differs from the saved one. If no calibration device is set up, starting the Flow shows the message Set up a calibration device before running the Flow.

While the calibration Flow runs, Steps 1-2 are locked ("Locked while a Calibration Flow is running. Stop the Flow to make changes.").

Step 4 — Validation​

The final step is to confirm the calibration is good before it takes effect. Review the results the system presents and verify they meet your expectations. Validation compares the new RMSE with the previous calibration (or the Factory baseline). Once you are satisfied that the calibration is correct, select Apply calibration so it becomes active on the Robot. Applying overwrites the active calibration and restarts the Control Unit. This cannot be undone, except by Roll back → Restore afterwards. Discard drops the result. Plan the restart: the Robot is unavailable until the Control Unit is back.

If the results do not look right, do not apply them. Go back through the earlier steps, check the camera image and sensor selection, and run the calibration again before validating.