Connecting the vision controller
Setting up the connection takes three steps: cable the vision controller to the Control Unit, give both ends an address on the same network, and add the device in RobFlow.
1. Cable it
The Photoneo vision controller has separate Ethernet ports for separate jobs. Two of them matter here:
| Vision controller port | Connect it to | Used for |
|---|---|---|
| Robot | The Control Unit's peripheral port | Requests from RobFlow and the Robot state stream |
| Network | Your factory network (optional) | Opening the Bin Picking Studio web interface from your computer |
The scanner itself goes into one of the Sensor ports, as described in Photoneo's Network setup chapter.
2. Set the network addresses
Both ends of the Robot cable need a static address in the same subnet.
On the Control Unit, the peripheral port has the address 192.168.1.1 with subnet mask
255.255.255.0 by default, so a manual setting is not necessary. Only if the vision controller
has to sit in a different subnet, change it under
Network Settings.
In Bin Picking Studio, open the Network page and edit the Robot interface:

| Bin Picking Studio field | What to enter |
|---|---|
| Vision controller → IPv4 address | The vision controller's address on this cable, for example 192.168.1.2 |
| Robot controller → IPv4 address | The Control Unit's peripheral port address, for example 192.168.1.1 |
| ARS port | Leave empty. The default is 11003, which is also RobFlow's default. |
| RSS port | 8888, or whatever you enter as Robot state port in RobFlow. The two must match. |
Save the section, then use Test connection to check that the vision controller can reach the Control Unit.
You need the web interface for this step. The vision controller's Network port gets its address by DHCP unless configured otherwise, so on a factory network you can open Bin Picking Studio from any computer on that network. Photoneo's Network setup and Remote access chapters describe the other ways in.
3. Add the device in RobFlow
Open Robot Configuration → Vision and choose Add Photoneo Device (Beta). A new device starts with Photoneo's default ports, and only the addresses need changing.
The button is only there on the Beta update channel. If you switch back to Stable, Photoneo devices disappear from the list but stay configured. Importing a Robot Configuration on Stable drops its Photoneo devices.

| Field | Meaning |
|---|---|
| Name | How the device is shown in Nodes and lists. Name it after the cell or the bin. |
| Robot port IP | Address of the vision controller's Robot port. RobFlow drives the device over it, and the Control Unit checks the connection on it. |
| Network port IP (optional) | Address of the vision controller's Network port. Only the Bin Picking Studio button uses it, so it has to be reachable from the computer you use RobFlow on. Leave it empty if you don't need the button. |
| Action port | The port RobFlow sends its requests to. Photoneo's default is 11003. |
| Robot state port | The port the Robot state is served on. Must match the RSS port set in Bin Picking Studio. |
| Solution ID | The solution that Camera Calibration runs for, as listed in the ID column of Bin Picking Studio's Solutions page. The first solution is 1. |
| Vision system ID | The vision system within that solution that gets calibrated. The first one is 1. |
The two IDs only decide what Camera Calibration calibrates. The picking Nodes take a solution and vision system of their own, and new Nodes fill these values in from the device.

Connection status
Each port is checked from where it is used. Both checks run when you open the device and every few seconds after that. The refresh button next to Device runs them right away, for example after fixing a cable.
Robot port, next to Device: the Control Unit checks that it reaches Bin Picking Studio over the Robot port, the link RobFlow uses.
| Status | Meaning |
|---|---|
| Connected | Bin Picking Studio answered. Its version is shown next to the Bin Picking Studio button. |
| Unrecognized | Something answered on that address, but it is not Bin Picking Studio. The IP address is most likely wrong. |
| Not reachable | Nothing answered. Check power, cabling and addresses. The reason is shown below the button. |
| Not checked | The address is not a valid IP address yet. |
Network port, next to the Bin Picking Studio button: your browser checks that it reaches the Network port, which is all the button needs.
| Status | Meaning |
|---|---|
| Reachable from this computer | The button opens Bin Picking Studio in a new browser tab. |
| Not reachable from this computer | The button will not work from this computer. RobFlow itself is not affected. |
With the Network port IP left empty, the button is disabled and no check runs.
The Robot port status checks Bin Picking Studio's web interface. It does not prove that the Robot state stream is connected. Bin Picking Studio shows that on its Deployment page as Robot State Server: CONNECTED.
Next step