Photoneo Skip Part
Beta
This Node is in Beta and may change. It appears in the Add Item menu only when the Robot's update channel is set to Beta and a Photoneo device is configured in Robot Configuration → Vision. See Photoneo Bin Picking.
The Photoneo Skip Part Node tells Bin Picking Studio that the last planned pick failed. The next Photoneo Pick then gets another part from the same scan instead of the same one again. It does not move the Robot.
Use it when:
- Photoneo Pick took its Error output because Bin Picking Studio found a part but could not plan a path to it.
- Your Flow detected a failed grasp, for example because a vacuum or gripper sensor reports no part after Attach. Bin Picking Studio cannot know that by itself.
Follow it with another Photoneo Pick.
Settings
| Setting | Meaning |
|---|---|
| Photoneo Device | The vision controller to tell. |
| Vision System ID | The vision system whose last pick failed. |
Outputs
| Output | Runs when |
|---|---|
| Output | Bin Picking Studio was told. |
| Error | The vision controller could not be reached or refused the request. The reason is in the message log. |