Add Calibration Sample

info

Robot Calibration is under Robot Configuration → Calibration. This Node is offered only in the Calibration Editor, in the Calibration category of the Add Item menu — not in the Flow or Subflow editor. See Robot Calibration.

Each time it runs, this Node waits a few seconds for the Robot to settle, measures the calibration target with the device chosen for the calibration — a Camera on a RobVision Device, or a Laser Tracker — and adds a sample to the calibration in progress: the Robot's joint angles with the measured target pose. The calibration is optimized again after every sample.

There is nothing to set on the Node. Selected, it shows the calibration device (name and type), or No device selected with "Set one up in Robot Config → New Calibration". Without a selected device the Node does nothing and the Flow continues.

Sample collection tips​

If the target can not be detected, a sample will not be added. Therefore, it is important to make sure the calibration target remains visible as much as possible while collecting samples. RobFlow then logs Calibration sample <n> discarded: detection too unstable. and the Flow continues.

How many samples to collect and how to vary the joints: see Collecting samples: maximize joint coverage.

The collected samples are listed under Robot Configuration → Calibration, step Calibrate, in Collected Movements, with the fit in Metrics. The Calibration Editor shows the same while the Flow runs.