Skip to main content
Version: v9

Add Calibration Point

Beta

This Node is in Beta and may change. It is only available in the Camera Calibration Editor of a Photoneo device, on the Beta update channel. See Camera calibration.

The Add Calibration Point Node asks Bin Picking Studio to capture one calibration point at the Robot's current Pose: it scans the calibration object and records where the Robot is. Place one after each movement Node of a calibration Flow.

The Node has nothing to configure. It sends the point to the Photoneo device the calibration Flow was last selected or opened for in Camera Calibration, so the same calibration Flow can be used for several devices. The Node shows which device that is.

Behavior​

  • Run from the editor: the point goes into the calibration opened on Bin Picking Studio's Calibration page. This is how the first calibration is run.
  • Started with Start Calibration Flow: the point goes into the automatic calibration RobFlow opened for the run.
  • No device selected yet: if the Flow was never selected or opened for a Photoneo device, the Node is skipped.
  • Run from here: Add Calibration Point Nodes before the Node you start from are skipped, because the Robot never moves to their Poses.
  • The point is rejected or cannot be captured: the Flow does not stop. The reason is logged and shown in Camera Calibration, and the Flow continues with the next Pose.

Output​

OutputRuns when
OutputAlways, once the point was captured, rejected or skipped.