Dashboard settings

Each Dashboard carries a small set of settings that control how it is identified and who may open it. Open them with Dashboard Config at the bottom of the Dashboard Editor. Closing the dialog saves the Dashboard.

Name and description​

The Dashboard Name identifies the Dashboard in the selector and in the Dashboard Viewer.

The description is free text. It is worth using on any installation with more than a couple of Dashboards, to record which station or shift a Dashboard is meant for.

Protected (needs login)​

A Dashboard with Protected (needs login) checked requires a RobFlow login before it will open. Unprotected Dashboards open for anyone who can reach the Robot.

In the Dashboard selector, protected Dashboards are marked, and show whether the current session is Authenticated or still Needs login.

Protect any Dashboard that can move the Robot or drive an output — anything carrying jogging, Free Motion, Set Outputs, Set Payload or brake control. Leave read-only status Dashboards unprotected so an operator can see what the cell is doing without signing in.

The login itself is configured under Network and access.

note

Protection decides who may open a Dashboard. Who may operate the Robot from it is separate: only the session that holds Robot control can — see Single point of control. A protected Dashboard opened by its address waits for the login before anything of it is shown.

Prevent kiosk breakout​

Kiosk mode hides the app bar so a Dashboard fills the screen. By default the operator can leave kiosk mode again with an on-screen button, which brings the app bar — and with it the rest of RobFlow — back.

The checkbox Prevent kiosk breakout (leave kiosk mode and show the app bar again) removes that button. The Dashboard then stays full-screen and the operator cannot navigate out of it.

note

This is a usability boundary, not a security one. Someone with access to the browser can still change the URL. For a real restriction, mark the Dashboards you want to protect as protected as well, so the rest of RobFlow requires a login.

warning

Enable Prevent kiosk breakout only once the Dashboard is finished and tested. With it on and no way back to the app bar, the practical route to changing anything is another device.