flow_state, robot_state and safety_state contain concrete values and abstract groupings:

  • Concrete identifies one exact publishable state.
  • Abstract grouping is a numeric parent for related states. A value ending in one zero covers its ten-value range; a value ending in two zeroes covers its hundred-value range. This is a range convention, not a bit mask.
  • Abstract/temporary may also be published while a specific state is not yet available.

PLC logic must handle the exact numeric value received, including group values.

Table: flow_state Values​

This field publishes the backend's OperationMode values. It reports the flow/teach mode and is independent of cmd_id. The backend forwards these values without a PROFINET-specific renumbering. The Core Output requested_operation_mode field does not select a state; see Legacy operation-mode byte.

ValueNameClassification
100TEACHconcrete
200FLOWabstract grouping
210FLOW_CONTINUOUSabstract grouping
211FLOW_CONTINUOUS_RUNNINGconcrete
212FLOW_CONTINUOUS_RESUMEconcrete
220FLOW_CONTINUOUS_PAUSED_STATESabstract grouping
221FLOW_CONTINUOUS_PAUSED_ON_TRAJECTORYconcrete
222FLOW_CONTINUOUS_PAUSED_NOT_ON_TRAJECTORYconcrete
500ERRORconcrete
600CRITICALconcrete

Table: robot_state Values​

ValueNameClassification
100IDLE_STATESabstract grouping
101DISABLEDconcrete
102SWITCHED_ONconcrete
103IDLEconcrete
104TRANSITIONconcrete
110IDLE_PAUSED_STATESabstract grouping
111IDLE_PAUSED_ON_TRAJECTORYconcrete
112IDLE_PAUSED_NOT_ON_TRAJECTORYconcrete
200MOVINGabstract/temporary
210MOVING_COMMANDabstract grouping
211MOVING_PTPconcrete
212MOVING_LINEARconcrete
213RESUMEconcrete
220DECELERATINGconcrete
221STREAMINGconcrete
222ROS_CONTROLconcrete
230MANUAL_MOVEMENTabstract grouping
231JOGGINGconcrete
232HAND_GUIDINGconcrete
500ERRORabstract grouping
510CONNECTION_ERRORabstract grouping
511BACKEND_CONNECTION_ERRORreserved/completeness
512CONTROLLER_CONNECTION_ERRORconcrete
513ROBOT_CONNECTION_ERRORconcrete
514UNKNOWN_CONTROLLER_API_VERSION_ERRORconcrete
515INVALID_CONTROLLER_API_VERSION_ERRORconcrete
520MOVEMENT_ERRORabstract grouping
521CLOSE_TO_SINGULARITY_ERRORconcrete
522LINEAR_MOTION_ERRORconcrete
523VELOCITY_ERRORconcrete
524INVALID_APPROACH_MODE_ERRORconcrete
525ANGLE_OUT_OF_LIMIT_ERRORconcrete
530MODULE_ERRORgrouping/concrete fallback
531MODULE_OVERHEAT_ERRORconcrete
600CRITICALconcrete

Table: safety_state Values​

ValueNameClassification
100MANUALconcrete
200AUTOconcrete
300SAFE_STOPabstract grouping
301SAFE_STOP_0concrete
302SAFE_STOP_1concrete
303SAFE_STOP_2concrete
304INVALIDconcrete; invalid safety-mode selection
500ERRORconcrete
501NOT_CONNECTEDconcrete