TIA Portal Setup
RobCo_PROFINET_v2.0.0.zip contains everything this manual refers to: the GSDML and BMP files, both UDT files, the TIA Portal V19 demo project, and this manual as a PDF.
Handover files
Keep these files together:
GSDML-V2.45-RobCo_GmbH-ModularRobot-20260901.xmlGSDML-079e-0001-Favicon.bmpRobCo_Datatypes.udtRobCo_Profinet_Variables.udt
RobCo_Datatypes.udt defines the fixed process image. The second file is a
project-specific typed AuxVariable overlay and is replaced by the RobFlow
export whenever the configured Variables change.
Use the type names from the supplied RobCo_Datatypes.udt, as listed in
Create PLC tags. Older demo projects used the names
RobCo_Profinet_CartesianPose and RobCo_Profinet_JointPose; update those
project types and their references to match the supplied definitions before
importing an AuxVariable overlay. A type-name change does not change the wire
layout.
Install and add the device
- Select
Options->Manage general station description files (GSD). - Select the directory containing the XML and BMP files and install the GSDML.
- Add
RobCo Modular RobotfromOther field devices->PROFINET IO->I/O->RobCo GmbH->RobCo Devices. - Connect the device PN/IE port to the PLC IO system.
Do not use the RobCo-internal networks 192.168.3.0/24 or 192.168.4.0/24
for the customer Profinet network.
Assign device name and IP
- Open the RobCo device under the PLC Profinet IO system.
- Select
Online & diagnostics->Functions->Assign PROFINET device name. - Refresh accessible devices and use the signal LED for identification.
- Assign the station name configured in the TIA project.
The IO controller assigns the configured IP address by DCP.