TIA Portal Setup

Download

RobCo_PROFINET_v2.0.0.zip contains everything this manual refers to: the GSDML and BMP files, both UDT files, the TIA Portal V19 demo project, and this manual as a PDF.

Handover files​

Keep these files together:

  • GSDML-V2.45-RobCo_GmbH-ModularRobot-20260901.xml
  • GSDML-079e-0001-Favicon.bmp
  • RobCo_Datatypes.udt
  • RobCo_Profinet_Variables.udt

RobCo_Datatypes.udt defines the fixed process image. The second file is a project-specific typed AuxVariable overlay and is replaced by the RobFlow export whenever the configured Variables change.

Use the type names from the supplied RobCo_Datatypes.udt, as listed in Create PLC tags. Older demo projects used the names RobCo_Profinet_CartesianPose and RobCo_Profinet_JointPose; update those project types and their references to match the supplied definitions before importing an AuxVariable overlay. A type-name change does not change the wire layout.

Install and add the device​

  1. Select Options -> Manage general station description files (GSD).
  2. Select the directory containing the XML and BMP files and install the GSDML.
  3. Add RobCo Modular Robot from Other field devices -> PROFINET IO -> I/O -> RobCo GmbH -> RobCo Devices.
  4. Connect the device PN/IE port to the PLC IO system.

Do not use the RobCo-internal networks 192.168.3.0/24 or 192.168.4.0/24 for the customer Profinet network.

Assign device name and IP​

  1. Open the RobCo device under the PLC Profinet IO system.
  2. Select Online & diagnostics -> Functions -> Assign PROFINET device name.
  3. Refresh accessible devices and use the signal LED for identification.
  4. Assign the station name configured in the TIA project.

The IO controller assigns the configured IP address by DCP.